Phensuximide Capsules
» Phensuximide Capsules contain not less than 93.0 percent and not more than 107.0 percent of the labeled amount of C11H11NO2.
Packaging and storage
Preserve in tight containers.
Identification
A:
The contents of Capsules respond to Identification test A under Phensuximide.
B:
The retention time exhibited by phensuximide in the chromatogram of the Assay preparation corresponds to that of phensuximide in the chromatogram of the Standard preparation, as obtained in the Assay.
Dissolution
Medium:
water; 900 mL.
Apparatus 1:
100 rpm.
Time:
120 minutes.
Procedure
Determine the amount of C11H11NO2 dissolved, employing the procedure set forth in the Assay, making any necessary modifications.
Tolerances
Not less than 75% (Q) of the labeled amount of C11H11NO2 is dissolved in 120 minutes.
Uniformity of dosage units
Assay
Mobile phase
Prepare a filtered and degassed mixture of water and acetonitrile (55:45). Make adjustments if necessary (see System Suitability under Chromatography
Standard preparation
Dissolve an accurately weighed quantity of USP Phensuximide RS in Mobile phase to obtain a solution having a known concentration of about 1 mg per mL.
Assay preparation
Place 10 Capsules in a 500-mL volumetric flask, and add 280 mL of water. Sonicate in a water bath at 40
Chromatographic system
(see Chromatography
Procedure
Separately inject equal volumes (about 20 µL) of the Standard preparation and the Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of C11H11NO2 per Capsule taken by the formula:
2500(C / V)(rU / rS)
in which C is the concentration, in mg per mL, of USP Phensuximide RS in the Standard preparation, V is the volume, in mL, of specimen solution taken for the Assay preparation, and rU and rS are the phensuximide peak responses obtained from the Assay preparation and the Standard preparation, respectively.
Auxiliary Information
Please check for your question in the FAQs before contacting USP.
USP35NF30 Page 4292
|