Hydromorphone Hydrochloride Oral Solution
DEFINITION
Hydromorphone Hydrochloride Oral Solution contains NLT 90.0% and NMT 110.0% of the labeled amount of hydromorphone hydrochloride (C17H19NO3·HCl). It may contain suitable preservatives.
IDENTIFICATION
Delete the following:
Blank:
0.01 N hydrochloric acid and water (4:1)
Standard solution:
0.04 mg/mL of USP Hydromorphone Hydrochloride RS in 0.01 N hydrochloric acid and water (4:1)
Sample solution:
Equivalent to 0.2 mg/mL of hydromorphone hydrochloride in water
Analysis:
Pretreat a solid phase extraction column containing L1 packing serially with about 10 mL of methanol, and about 10 mL of 0.01 N hydrochloric acid. Transfer 5.0 mL of the Sample solution to the column, add about 19 mL of 0.01 N hydrochloric acid in at least two portions, and elute into a 25-mL volumetric flask. Dilute with 0.01 N hydrochloric acid to volume, and mix. Using a suitable cell, compare the spectrum of the Sample solution with that of the Standard solution, using the Blank to zero the instrument.
Acceptance criteria:
The absorption spectrum of the Sample solution exhibits maxima and minima at the same wavelength as that of the Standard solution.
Change to read:
• ASSAY
• Procedure
Diluent:
Phosphoric acid and water (1:1000)
Solution A:
1.0 mg/mL of sodium 1-heptanesulfonate monohydrate in methanol and water (1:9). To each liter of this solution add 1.0 mL of triethylamine, and adjust with phosphoric acid to a pH of 2.5 ± 0.1.
Solution B:
1.0 mg/mL of sodium 1-heptanesulfonate monohydrate in methanol and water (1:1). To each liter of this solution add 1.0 mL of triethylamine, and adjust with phosphoric acid to a pH of 2.5 ± 0.1.
Mobile phase:
See Table 1.
Table 1
[NoteThe Standard solution and Sample solution should be kept in a cool place, protected from light. ]
Standard solution:
0.08 mg/mL of USP Hydromorphone Hydrochloride RS in Diluent
Sample solution:
Equivalent to 0.08 mg/mL of hydromorphone hydrochloride by diluting a suitable volume of Oral Solution in Diluent
Chromatographic system
Mode:
LC
Detector:
UV 220 nm
Column:
4.6-mm × 5-cm; 3.5-µm packing L1
Column temperature:
45
Flow rate:
1 mL/min
Injection size:
20 µL
System suitability
Sample:
Standard solution
Suitability requirements
Tailing factor:
NMT 1.5 for the hydromorphone peak
Relative standard deviation:
NMT 2.0%
Analysis
Samples:
Standard solution and Sample solution
Calculate the percentage of the labeled amount of hydromorphone hydrochloride (C17H19NO3 ·HCl) in the portion of Oral Solution taken:
Result = (rU/rS) × (CS/CU) × 100
Acceptance criteria:
90.0%110.0%
IMPURITIES
• Organic Impurities
Diluent, Solution A, and Solution B:
Prepare as directed in the Assay.
Mobile phase:
See Table 2.
Table 2
[NoteThe System suitability solution, Quantitation limit solution, Standard solution, and Sample solution should be kept in a cool place, protected from light. ]
System suitability solution:
0.8 mg/mL of USP Hydromorphone Hydrochloride RS and 0.8 µg/mL of USP Hydromorphone Related Compound A RS in Diluent
Quantitation limit solution:
0.4 µg/mL of USP Hydromorphone Hydrochloride RS in Diluent
Standard solution:
4 µg/mL of USP Hydromorphone Hydrochloride RS in Diluent
Sample solution:
Equivalent to 0.4 mg/mL of hydromorphone hydrochloride in Diluent
Chromatographic system
Mode:
LC
Detector:
UV 220 nm
Column:
3.9-mm × 15-cm; 5-µm packing L1
Column temperature:
45
Flow rate:
1 mL/min
Injection size:
20 µL
System suitability
Samples:
System suitability solution, Quantitation limit solution, and Standard solution
Suitability requirements
Resolution:
NLT 1.0 between the hydromorphone related compound A and hydromorphone peaks, System suitability solution
Signal-to-noise ratio:
10:1, Quantitation limit solution
Tailing factor:
NMT 1.5 for the hydromorphone peak, Standard solution
Relative standard deviation:
NMT 5.0%, Standard solution
Analysis
Samples:
Diluent, Standard solution, and Sample solution
Calculate the percentage of any specified or unspecified impurity in the portion of Oral Solution taken:
Result = (rU/rS) × (CS/CU) × (1/F) × 100
Calculate the total degradation products by summing the percentage of all individual specified and unspecified degradation products determined to be at a level of 0.1% or greater, excluding the known process impurities, as indicated in Table 3.
Acceptance criteria:
See Table 3.
[NoteDisregard peaks corresponding to those from the Diluent, peaks that elute before a relative retention time of about 0.50, except for any peak with a relative retention time of about 0.34, and peaks that elute at the relative retention times of the process-related substances designated in Table 3. ]
Table 3
SPECIFIC TESTS
• Microbial Enumeration Tests
• pH
ADDITIONAL REQUIREMENTS
• Packaging and Storage:
Preserve in tight containers, protected from light. Store at 25
• Labeling:
Identify in the product labeling any preservative used in the Oral Solution.
• USP Reference Standards
USP Hydromorphone Related Compound A RS
Auxiliary Information
Please check for your question in the FAQs before contacting USP.
USP35NF30 Page 3448