|
IgG-Coated Red Cells Red cells coated with human immunoglobulin (IgG). The reagent must be obtained from manufacturers or suppliers licensed by the Center for Biologics Evaluation and Research, Food and Drug Administration. The use of reagents from an unlicensed manufacturer or supplier may invalidate the results.
[noteThere are many manufacturers and suppliers of these reagents that are licensed by the Center for Biologics Evaluation and Research, Food and Drug Administration. Some examples of licensed manufacturers or suppliers are the following: Gamma Biologics, Houston, TX; and Ortho Diagnostics, Raritan, NJ.]
Imidazole, Indene,
Assay
Inject an appropriate specimen into a suitable gas chromatograph (see Chromatography
Refractive index
Indicators See separate subsection. Indigo Carmine Use Indigotindisulfonate Sodium. Indole (2,3-Benzopyrrole), Indole-3-carboxylic Acid, Inositol (Hexahydroxycyclohexane),
Loss on drying
Residue on ignition (Reagent test):
not more than 0.1%.
Iobenguane Sulfate (m-Iodobenzylguanidine Hemisulfate Salt),
Assay
When tested by thin-layer chromatography, with the use of plates coated with chromatographic silica gel mixture, a developing system consisting of a mixture of butyl alcohol, water, and acetic acid (60:25:15), and examined under short-wavelength UV light, not more than a single impurity spot of not more than 0.5% is observed.
Iodic Acid, Iodine, Iodine Monobromide,
Assay
Place about 100 mL of acetic acid in a 150-mL beaker. Separately dissolve 2 g of potassium iodide in a minimum volume of water, add this solution to the acetic acid, and mix. Transfer about 200 mg of Iodine Monobromide, accurately weighed, to the beaker containing the potassium iodide and acetic acid mixture, and stir to dissolve. Titrate immediately with 0.1 N sodium thiosulfate VS, determining the endpoint potentiometrically (see Titrimetry
Iodine Monochloride, Iodoethane, p-Iodonitrotetrazolium Violet, (2-(4-Iodophenyl)-3-(4-nitrophenyl)-5-phenyltetrazolium chloride),
Assay
When tested by thin-layer chromatography, with the use of plates coated with chromatographic silica gel mixture and a developing system consisting of a mixture of amyl alcohol, formic acid, and water (8:1:1), sprayed with 0.1% sodium thiosulfate solution, and examined under short-wavelength UV light, a single spot is exhibited, with trace impurities.
Ion-Exchange Resin An intimate mixture of 4 parts of a strongly acidic cation-exchanger in the hydrogen form (produced by sulfonation of a styrene-divinylbenzene copolymer, representing 8 to 10% divinylbenzene) and 6 parts of a strongly basic anion-exchanger in the hydroxyl form (produced by amination with trimethylamine of a chloromethylated styrene-divinylbenzene copolymer, representing 3 to 5% divinylbenzene). Iron Wire, Isoamyl Alcohol Use Amyl Alcohol. Isobutyl Acetate,
Assay
Inject an appropriate specimen into a suitable gas chromatograph (see Chromatography
Specific gravity
Refractive index
Isobutyl Alcohol (2-Methyl-1-propanol), 4-Isobutylacetophenone, N-Isobutylpiperidone, Isoflupredone Acetate (9- Isomaltotriose ( Isonicotinic Acid, Isonicotinic Acid Hydrazide Use Isoniazid. Isooctane See 2,2,4-Trimethylpentane. Isopropyl Acetate, Isopropyl Alcohol (2-Propanol),
[noteFor use in assays and tests involving UV spectrophotometry, use ACS reagent grade Isopropyl Alcohol Suitable for Use in UV Spectrophotometry.]
Isopropyl Alcohol, Dehydrated Isopropyl Ether See Diisopropyl Ether. Isopropyl Iodide (2-Iodopropane), Isopropyl Myristate,
pH of water extract
Transfer 100 mL to a 250-mL centrifuge bottle, add 10 mL of twice-distilled water, close the bottle with a suitable closure, and shake vigorously for 60 minutes. Centrifuge the mixture at 1800 rpm for 20 minutes, aspirate the upper (isopropyl myristate) layer, and determine the pH of the residual water layer: the pH is not less than 6.5.
Isopropyl Myristate not conforming to the test for pH of water extract may be rendered suitable for use in sterility test procedures as follows:
Using a 20-mm × 20-cm glass column, add activated alumina, and tamp down to a height of 15 cm. Pass 500 mL of the isopropyl myristate through the column, using a slight positive pressure to maintain an even flow, and use the eluate collected directly in the sterility test procedure.
Isopropyl Salicylate,
Assay
Inject an appropriate specimen into a suitable gas chromatograph (see Chromatography
Isopropylamine (2-Aminopropane),
Assay
Transfer about 0.2 g, accurately weighed, to a suitable container, add 50 mL of water, and mix. Titrate with 0.1 N hydrochloric acid VS, using a mixture of bromocresol green TS and methyl red TS (5:1) as indicator. Each mL of 0.1 N hydrochloric acid is equivalent to 59.11 mg of C3H9N. Not less than 98% is found.
Boiling range (Reagent test)
Not less than 95% distills between 31
Refractive index
Isorhamnetin,
Melting point:
greater than 300
Isovaleric Acid |