Theophylline and Guaifenesin Oral Solution
» Theophylline and Guaifenesin Oral Solution contains not less than 90.0 percent and not more than 110.0 percent of the labeled amount of anhydrous theophylline (C7H8N4O2) and not less than 86.7 percent and not more than 113.3 percent of the labeled amount of guaifenesin (C10H14O4).
Packaging and storage— Preserve in tight containers.
Identification— Transfer a volume of Oral Solution, equivalent to about 150 mg of theophylline, to a separator, add 15 mL of water, and proceed as directed in the Identification test under Theophylline and Guaifenesin Capsules, beginning with “To a second separator.”
Alcohol content (if present), Method II 611: between 90.0% and 110.0% of the labeled amount of C2H5OH, determined by the gas-liquid chromatographic procedure, acetone being used as the internal standard.
Assay—
pH 6.5 buffer solution and Mobile phase—Prepare as directed in the Assay under Theophylline and Guaifenesin Capsules.
Caffeine solution— Dissolve about 400 mg of caffeine in 1000 mL of a mixture of methanol and water (90:10), and mix.
Standard preparation— Dissolve an accurately weighed quantity of USP Theophylline RS in pH 6.5 buffer solution, and dilute quantitatively with pH 6.5 buffer solution to obtain a solution (Solution T) having a known concentration of about 900J µg per mL, in which J is the ratio of the labeled amount of theophylline to that of guaifenesin. Transfer about 90 mg of USP Guaifenesin RS, accurately weighed, to a 200-mL volumetric flask, add about 150 mL of pH 6.5 buffer solution, shake to dissolve, dilute with pH 6.5 buffer solution to volume, and mix. Pipet 10 mL of this solution and 5 mL of Solution T into a 50-mL volumetric flask, dilute with Mobile phase to volume, and mix to obtain a Standard preparation having known concentrations of about 90 µg of guaifenesin and about 90J µg of theophylline per mL.
Assay preparation— Transfer an accurately measured volume of Oral Solution, equivalent to about 90 mg of guaifenesin, to a 200-mL volumetric flask, dilute with pH 6.5 buffer solution to volume, and mix. Transfer 10.0 mL of this solution to a 50-mL volumetric flask, dilute with Mobile phase to volume, and mix.
Chromatographic system (see Chromatography 621)—The liquid chromatograph is equipped with a 280-nm detector and a 3.9-mm × 30-cm column that contains packing L1. The flow rate is about 1.0 mL per minute. Chromatograph a mixture of 4 mL of Standard preparation and 1 mL of Caffeine solution, and record the peak responses as directed for Procedure: the resolution, R, between the theophylline and caffeine peaks is not less than 3.0, and the relative standard deviation for replicate injections is not more than 2.0 for theophylline and not more than 2.5% for guaifenesin.
Procedure— Proceed as directed in the Assay under Theophylline and Guaifenesin Capsules. Calculate the quantities, in mg, of anhydrous theophylline (C7H8N4O2) and guaifenesin (C10H14O4) per mL of the Oral Solution taken by the formula:
(C / V)(rU / rS)
in which C is the concentration, in µg per mL, of the appropriate USP Reference Standard in the Standard preparation, V is the volume, in mL, of Oral Solution taken, and rU and rS are the peak responses of the corresponding analyte in the Assay preparation and the Standard preparation, respectively.
Auxiliary Information— Please check for your question in the FAQs before contacting USP.
Topic/Question Contact Expert Committee
Monograph Daniel K. Bempong, Ph.D.
Senior Scientist
1-301-816-8143
(MDPS05) Monograph Development-Pulmonary and Steroids
Reference Standards Lili Wang, Technical Services Scientist
1-301-816-8129
RSTech@usp.org
USP32–NF27 Page 3713
Chromatographic Column—
Chromatographic columns text is not derived from, and not part of, USP 32 or NF 27.