Misoprostol
(mye'' soe prost' ol).
C22H38O5 382.53 Prost-13-en-1-oic acid, 11,16-dihydroxy-16-methyl-9-oxo-, methyl ester, (1R*,2R*,3R*,E)-; (±)-Methyl (1R,2R,3R)-3-hydroxy-2-[(E)-(4RS)-4-hydroxy-4-methyl-1-octenyl]-5-oxocyclopentaneheptanoate DEFINITION
Misoprostol contains NLT 97.0% and NMT 102.0% of C22H38O5, calculated on the anhydrous basis.
IDENTIFICATION
• B.
The retention time of the major peak of the Sample solution corresponds to that of the Standard solution, as obtained in the Assay.
ASSAY
• Procedure
Mobile phase:
2,2,4-Trimethylpentane, dioxane, and acetonitrile (78:21.5:0.5)
Standard solution:
5.0 mg/mL of USP Misoprostol RS in Mobile phase
Sample solution:
5.0 mg/mL of Misoprostol in Mobile phase
Chromatographic system
Mode:
LC
Detector:
UV 210 nm
Column:
4.6-mm × 25-cm; 5-µm packing L3
Flow rate:
2 mL/min
Injection size:
20 µL
System suitability
Sample:
Standard solution
[NoteIdentify the impurities based on the retention times shown in Impurity Table 1. ]
Suitability requirements
Resolution:
NLT 1.2, between the second diastereomer peak for 12-epimisoprostol and the Misoprostol peak
Relative standard deviation:
NMT 1.0%, for three replicate injections
Analysis
Samples:
Standard solution and Sample solution
Calculate the percentage of C22H38O5 in the portion of Misoprostol taken:
Result = (rU/rS) × (CS/CU) × 100
Acceptance criteria:
97.0%102.0% on the anhydrous basis
IMPURITIES
Organic Impurities
• Procedure 1
Mobile phase, Standard solution, Sample solution, Chromatographic system, and System suitability:
Proceed as directed in the Assay.
Analysis
Samples:
Standard solution and Sample solution
Record the chromatogram for at least 3 times the retention time of the Misoprostol peak, and measure the peak responses. Identify the impurities based on the retention times shown in Impurity Table 1.
Calculate the percentage of each impurity in the portion of Misoprostol taken:
Result = (rU/rS) × (CS/CU) × (1/F) × 100
Acceptance criteria
Individual impurities:
See Impurity Table 1.
Total impurities:
NMT 1.5%
Impurity Table 1
• Procedure 2: Content of Diastereomers
Mobile phase:
Hexane, ethanol, and isopropyl alcohol (94:4:2)
Sample solution:
1.0 mg/mL of Misoprostol in Mobile phase
Chromatographic system
Mode:
LC
Detector:
UV 205 nm
Column:
4.6-mm × 25-cm; 5-µm packing L3
Column temperature:
40
Flow rate:
1 mL/min
Injection size:
20 µL
System suitability
Sample:
Sample solution
[NoteIdentify the components based on their relative retention times which are about 0.92 for the first diastereomer peak and 1.0 for the second diastereomer peak. ]
Suitability requirements
Resolution:
NLT 2.0, between the two diastereomer peaks
Relative standard deviation:
NMT 2.0% from the area of the first diastereomer peak
Analysis
Sample:
Sample solution
Calculate the fraction of the first diastereomer in the portion of Misoprostol taken:
Result = r1/(r1+ r2)
Acceptance criteria
Fraction of the first diastereomer:
0.510.56
SPECIFIC TESTS
• Water Determination, Method Ic
ADDITIONAL REQUIREMENTS
• Packaging and Storage:
Preserve in tight containers, and store in a freezer.