|
Methylcellulose (meth'' il sel' ue lose).
Legend: + will adopt and implement; In EP, Viscosity and Assay will be dealt with in the non-mandatory Functionality-Related Characteristics section. The assay limits will not be included in the Definition (EP). Nonharmonized attributes: Packaging and Storage Specific local attributes: Appearance of solution (EP), Description (JP), Limit of glyoxal (EP). Cellulose, methyl ether; Cellulose methyl ether DEFINITION Methylcellulose is a methyl ether of cellulose. When dried at 105 IDENTIFICATION • A. Procedure Analysis: Evenly distribute 1.0 g onto the surface of 100 mL of water in a beaker, tapping the top of the beaker gently, if necessary, to ensure a uniform layer on the surface, and allow to stand for 12 min. Acceptance criteria: The powdered material aggregates on the surface. • B. Procedure Analysis: Evenly distribute 1.0 g into 100 mL of boiling water, and stir the mixture using a magnetic stirrer with a 25-mm long bar: a slurry is formed and the particles do not dissolve. Allow the slurry to cool to 5 Acceptance criteria: A clear or slightly turbid solution occurs with its thickness dependent on the viscosity grade. • C. Procedure Analysis: To 0.1 mL of the sample solution obtained in Identification test B add 9 mL of diluted sulfuric acid (9 in 10), shake, heat in a water bath for exactly 3 min, immediately cool in an ice bath, add carefully 0.6 mL of ninhydrin TS, shake, and allow to stand at 25 Acceptance criteria: A red color develops immediately, and it does not change to purple within 100 min. • D. Procedure Analysis: Add 23 mL of the solution obtained in Identification test B onto a glass slide as a thin film and allow the water to evaporate. Acceptance criteria: A coherent, clear film forms on the glass slide. • E. Procedure Analysis: Add exactly 50 mL of the sample solution obtained in Identification test B to exactly 50 mL of water in a beaker. Insert a thermometer into the solution. Stir the solution on a magnetic stirrer/hot plate and begin heating at a rate of 2 Acceptance criteria: The flocculation temperature is higher than 50 ASSAY • Procedure [CautionPerform all steps involving Hydriodic acid carefully, in a well-ventilated hood. Use goggles, acid-resistant gloves, and other appropriate safety equipment. Be exceedingly careful when handling the hot vials, because they are under pressure. In the event of hydriodic exposure, wash with copious amounts of water, and seek medical attention at once. ] Apparatus Reaction vial: A 5-mL pressure-tight serum vial, 20 mm in outside diameter, 50 mm in height, and 20 mm in outside diameter and 13 mm in inside diameter at the mouth, equipped with a pressure-tight septum having a polytetrafluoroethylene-faced butyl rubber and an air-tight seal using an aluminum crimp or any sealing system that provides sufficient air tightness. Heater: A heating module with a square-shaped aluminum block having holes 20 mm in diameter and 32 mm in depth, so that the reaction vial fits. The heating module is also equipped with a magnetic stirrer capable of mixing the contents of the vial, or use a reciprocal shaker that performs a reciprocating motion of approximately 100 times/min. Hydriodic acid: Use a reagent having a specific gravity of at least 1.69, equivalent to 55%57% HI. Internal standard solution: 30 mg/mL of n-octane in o-xylene Standard solution: Into a suitable serum vial, weigh 60100 mg of adipic acid, add 2.0 mL of Hydriodic acid, then pipet 2.0 mL of Internal standard solution into the vial, and close the vial securely with a suitable septum stopper. Weigh the vial and contents, add 45 µL of methyl iodide with a syringe through the septum, weigh again, and calculate the weight of methyl iodide added, by difference. Shake, and allow the layers to separate. Use the upper layer as the Standard solution. Sample solution: Transfer 0.065 g of Methylcellulose to a 5-mL thick-walled reaction vial equipped with a pressure-tight septum closure, add 60100 mg of adipic acid, and pipet 2.0 mL of Internal standard solution into the vial. Cautiously pipet 2.0 mL of Hydriodic acid into the mixture, immediately secure the closure, and weigh it. Using a magnetic stirrer equipped in the heating module, or using a reciprocal shaker, mix the contents of the vial continuously for 60 min while heating the block so that the temperature of the contents is maintained at 130 ± 2 Chromatographic system Mode: GC Detector: Thermal conductivity or hydrogen flame ionization Column: 3- to 4-mm × 1.8- to 3-m column packed with 10%20% liquid phase G1, 125150 µm in diameter on 100- to 120-mesh support S1A Column temperature: 100 Carrier gas: Helium for the thermal conductivity detector, and helium or nitrogen for the hydrogen flame ionization detector Flow rate: Adjust so that the retention time of the internal standard is about 10 min. Injection size: 1 or 2 µL Analysis Samples: Standard solution and Sample solution Calculate the percentage of methoxy in the Methylcellulose taken: Result = 21.864 × (RU/RS) × (WS/W)
Acceptance criteria: 26.0%33.0% IMPURITIES Inorganic Impurities • Residue on Ignition • Heavy Metals, Method III Acceptance criteria: The color of the test solution is not darker than that of the control solution (NMT 20 ppm). SPECIFIC TESTS • Loss on Drying • Viscosity [NoteThe density is 1.00 g/mL, so there is no necessity for determining the density at every measurement in the case of having the confirmation data. ] Method 1: This method is applied to samples with a viscosity of less than 600 mPa·s. Weigh a quantity of Methylcellulose, equivalent to 4.000 g, calculated on the dried basis, transfer into a wide-mouth bottle, and add hot water to obtain the total weight of the sample and water of 200.0 g. Cap the bottle, and stir by mechanical means at 400 ± 50 rpm for 10 or 20 min until particles are thoroughly dispersed and wetted out. Scrape down the walls of the bottle with a spatula, if necessary, to ensure that there is no undissolved material on the sides of the bottle, and continue the stirring in a cooling water bath equilibrated at a temperature below 5 Method 2: This method is applied to samples with a viscosity of 600 mPa·s or higher. Weigh a quantity of Methylcellulose, equivalent to 10.00 g, calculated on the dried basis, transfer into a wide-mouth bottle, and add hot water to obtain the total weight of the sample and water of 500.0 g. Capping the bottle, stir by mechanical means at 400 ± 50 rpm for 1020 min until particles are thoroughly dispersed and wetted out. Scrape down the walls of the bottle with a spatula, if necessary, to ensure that there is no undissolved material on the sides of the bottle, and continue the stirring in a cooling water bath equilibrated at a temperature below 5 Apparatus: Brookfield type LV model or equivalent. Rotor No., revolution, and calculation multiplier: apply the conditions specified in the following table.
Operation of apparatus: Allow the spindle to rotate for 2 min before taking the measurement. Allow a rest period of 2 min between subsequent measurements. Repeat the operation to rotate the spindle specified above twice and average the three readings. Acceptance criteria: 80.0%120.0% of that stated on the label for viscosity types less than 600 mPa·s, and 75.0%140.0% of that stated on the label for viscosity types 600 mPa·s or higher • pH: Measure the pH of the solution prepared in the test for Viscosity at 20 ± 2 Acceptance criteria: 5.08.0 ADDITIONAL REQUIREMENTS • • Labeling: Label it to indicate its nominal viscosity type [viscosity of a solution (1 in 50)] in milli-Pascal second (mPa·s). Auxiliary Information Please check for your question in the FAQs before contacting USP.
USP35NF30 Page 3868 Pharmacopeial Forum: Volume No. 35(3) Page 683Chromatographic Column Chromatographic columns text is not derived from, and not part of, USP 35 or NF 30. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||