Cysteine Hydrochloride
(sis' te een hye'' droe klor' ide).
Click to View Image
Click to View USP ImageClick to View 3D Image

C3H7NO2S·HCl·H2O175.64

C3H7NO2S·HCl157.62
l-Cysteine hydrochloride monohydrate    [7048-04-6].
Anhydrous    [52-89-1].
DEFINITION
Cysteine Hydrochloride is l-cysteine hydrochloride monohydrate and contains NLT 98.5% and NMT 101.5% of l-cysteine hydrochloride (C3H7NO2S·HCl), calculated on the dried basis.
IDENTIFICATION
ASSAY
•  Procedure
Sample: 250 mg of Cysteine Hydrochloride
Blank: Proceed as directed in the Analysis without the Sample.
Titrimetric system 
Mode: Residual titration
Titrant: 0.1 N iodine VS
Back titrant: 0.1 N sodium thiosulfate VS
Endpoint detection: Visual
Analysis: Transfer the Sample to an iodine flask. Add 20.0 mL of water and 4 g of potassium iodide, and mix. Cool the solution in an ice bath, and add 5 mL of 3 N hydrochloric acid and 25.0 mL of 0.1 N iodine VS. Insert the stopper, and allow to stand in the dark for 20 min. Titrate the excess iodine with the Back titrant. Add 3 mL of starch TS as the endpoint is approached. Perform the Blank determination. Calculate the percentage of cysteine hydrochloride (C3H7NO2S·HCl) in the Sample taken:
Result = {[(VB VS) × N × F]/W} × 100
VB== Back titrant volume consumed by the Blank (mL)
VS== Back titrant volume consumed by the Sample (mL)
N == actual normality of the Back titrant (mEq/mL)
F== equivalency factor, 157.6 mg/mEq
W== Sample weight (mg)
Acceptance criteria: 98.5%–101.5% on the dried basis
IMPURITIES
•  Residue on Ignition 281: NMT 0.4%
•  Chloride and Sulfate, Sulfate 221
Standard solution: 0.10 mL of 0.020 N sulfuric acid
Sample: 0.33 g of Cysteine Hydrochloride
Acceptance criteria: NMT 0.03%.
•  Iron 241: NMT 30 ppm
•  Heavy Metals, Method I 231: NMT 15 ppm
•  Related Compounds
N-Ethylmaleimide solution: 40 mg/mL of N-ethylmaleimide in alcohol
Standard stock solution: Dissolve 20 mg of USP l-Cysteine Hydrochloride RS in 10.0 mL of water. Add 10.0 mL of N-Ethylmaleimide solution, and mix. Allow the solution to stand for 5 min before using.
Standard solution: 0.05 mg/mL from Standard stock solution in water. [Note—This solution has a concentration equivalent to 0.5% of that of the Sample solution. ]
System suitability solution: Transfer 10 mg of USP l-Tyrosine RS and 10 mL of the Standard stock solution to a 25-mL volumetric flask. Dilute with water to volume.
Sample stock solution: Transfer 0.2 g of Cysteine Hydrochloride to a 10-mL volumetric flask, dissolve, and dilute with water to volume.
Sample solution: To 5.0 mL of the Sample stock solution add 5.0 mL of N-Ethylmaleimide solution, and mix. Allow the solution to stand for 5 min before using.
Chromatographic system 
Mode: TLC
Adsorbent: 0.25-mm layer of chromatographic silica gel mixture
Application volume: 5 µL
Developing solvent system: Butyl alcohol, glacial acetic acid, and water (3:1:1)
Spray reagent: 2 mg/mL of ninhydrin in a mixture of butyl alcohol and 2 N acetic acid (95:5)
System suitability 
Suitability requirements: The chromatogram of the System suitability solution exhibits two clearly separated spots.
Analysis 
Samples: Standard solution, System suitability solution, and Sample solution.
After air-drying the plate, spray with Spray reagent, and heat between 100 and 105 for 15 min. Examine the plate under white light.
Acceptance criteria: Any secondary spot of the Sample solution is not larger or more intense than the principal spot of the Standard solution.
Individual impurities: NMT 0.5%
Total impurities: NMT 2.0%
SPECIFIC TESTS
•  Optical Rotation, Specific Rotation 781S
Sample solution: 80 mg/mL in 6 N hydrochloric acid
Acceptance criteria: +5.7 to +6.8
•  Loss on Drying 731: Dry a sample at room temperature at a pressure not exceeding 5 mm of mercury for 24 h: it loses 8.0%–12.0% of its weight.
ADDITIONAL REQUIREMENTS
•  Packaging and Storage: Preserve in well-closed containers.
•  USP Reference Standards 11
USP l-Cysteine Hydrochloride RS
USP l-Tyrosine RS Click to View Structure
Auxiliary Information— Please check for your question in the FAQs before contacting USP.
Topic/QuestionContactExpert Committee
MonographHuy T. Dinh, M.S.
Scientific Liaison
1-301-816-8594
(DS2010) Monographs - Dietary Supplements
Reference StandardsRS Technical Services
1-301-816-8129
rstech@usp.org
USP35–NF30 Page 2798
Pharmacopeial Forum: Volume No. 30(5) Page 1598
Chromatographic Column— 