Melengestrol Acetate
(mel'' en jes' trol as' e tate).
Click to View Image
C25H32O4 396.52

Pregna-4,6-diene-3,20-dione, 17-(acetyloxy)-6-methyl-16-methylene-.
17-Hydroxy-6-methyl-16-methylenepregna-4,6-diene-3,20-dione acetate [2919-66-6].
» Melengestrol Acetate contains not less than 97.0 percent and not more than 103.0 percent of C25H32O4, calculated on the dried basis.
Packaging and storage— Preserve in tight, light-resistant containers, and store at controlled room temperature.
Labeling— Label it to indicate that it is for veterinary use only.
USP Reference standards 11
USP Melengestrol Acetate RS Click to View Structure
USP Melengestrol Acetate Related Compound A RS
16-Methylene-17-hydroxy-4-pregnene-3,20-dione 17-acetate.
USP Melengestrol Acetate Related Compound B RS
17-Hydroxy-6,16-dimethyleneprogna-4-ene-3,20-dione 17-acetate.
Identification—
B: Ultraviolet Absorption 197U
Solution: 10 µg per mL.
Medium: alcohol.
C: The retention time of the melengestrol acetate peak in the chromatogram of the Assay preparation corresponds to that in the chromatogram of the Standard preparation, as obtained in the Assay.
Melting temperature 741: between 219 and 226.
Specific rotation 781S: between –132.0 and –122.0, at 20.
Test solution: 10.0 mg per mL, in chloroform.
Loss on drying 731 Dry it at 105 for 3 hours: it loses not more than 0.5% of its weight.
Heavy metals, Method II 231: not more than 0.001%.
Related compounds—
Mobile phase— Prepare a mixture of acetonitrile and water (50:50).
Standard solution— Dissolve an accurately weighed quantity of USP Melengestrol Acetate RS, USP Melengestrol Acetate Related Compound A RS, and USP Melengestrol Acetate Related Compound B RS in methanol to obtain a solution having known concentrations of about 0.005 mg of each per mL.
Test solution— Use the Assay preparation.
Chromatographic system (see Chromatography 621)— The liquid chromatograph is equipped with a multiwavelength detector set at 240 and 262 nm and a 4.6-mm × 25-cm column that contains 5-µm packing L7. The flow rate is about 1.0 mL per minute. Chromatograph the Standard solution, and record the peak responses as directed for Procedure [note—Melengestrol acetate and melengestrol related compound B will generate larger peak areas at 262 nm than at 240 nm; melengestrol acetate related compound A will generate a larger peak area at 240 nm than at 262 nm ] : the relative retention times are about 0.78, 1.0, and 1.05 for melengestrol acetate related compound A, melengestrol acetate, and melengestrol acetate related compound B, respectively; the resolution, R, between melengestrol acetate related compound A and melengestrol acetate related compound B is not less than 5.0; the column efficiency for the melengestrol acetate related compound A peak is greater than 1500 theoretical plates; the tailing factor is less than 2.0; and the relative standard deviation for replicate injections is not more than 5.0%.
Procedure— Separately inject equal volumes (about 20 µL) of the Standard solution and the Test solution into the chromatograph, record the chromatograms, identify the peaks, and determine which detector wavelength generates the larger peak area for each impurity. Using the larger peak area, calculate the percentage of each impurity in the portion of Melengestrol Acetate taken by the formula:
100(CS / CU)(ri / rS)
in which CS is the concentration, in mg per mL, of either melengestrol related compound A or melengestrol related compound B in the Standard solution [note—If using the impurity peak area generated at 240 nm, CS is the concentration of melengestrol related compound A; if using the impurity peak area generated at 262 nm, CS is the concentration of melengestrol related compound B ] ; CU is the concentration, in mg per mL, of melengestrol acetate in the Test solution; ri is the peak area of each impurity obtained from the Test solution; and rS is the peak area of either melengestrol related compound A or melengestrol related compound B obtained from the Standard solution [note—If using the impurity peak area generated at 240 nm, rS is the peak area of melengestrol related compound A; if using the impurity peak area generated at 262 nm, CS is the peak area of melengestrol related compound B ] : not more than 0.5% of any identified impurity is found; not more than 0.2% of any unidentified impurity is found; and not more than 1.0% of total impurities is found.
Assay—
Mobile phase— Prepare a mixture of acetonitrile and water (50:50).
Standard preparation— Dissolve an accurately weighed quantity of USP Melengestrol Acetate RS in methanol to obtain a solution having a known concentration of about 0.5 mg per mL.
Assay preparation— Transfer about 50 mg of Melengestrol Acetate, accurately weighed, to a 100-mL volumetric flask, and dissolve in and dilute with methanol to volume.
Chromatographic system (see Chromatography 621)— The liquid chromatograph is equipped with a 287-nm detector and a 4.6-mm × 25-cm column that contains 5-µm packing L7. The flow rate is about 1.0 mL per minute. Chromatograph the Standard preparation as directed for Procedure: the column efficiency is not less than 1500 theoretical plates; the tailing factor is not more than 2; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure— Separately inject equal volumes (about 20 µL) of the Standard preparation and the Assay preparation in duplicate into the chromatograph, record the chromatograms, and measure the areas for the major peaks. Calculate the quantity, in mg, of C25H32O4 in the portion of Melengestrol Acetate taken by the formula:
2CW(rU / rS)
in which C is the concentration, in mg per mL, of the Standard preparation; W is the weight, in mg, of Melengestrol Acetate used to prepare the Assay preparation; rU is the average peak area of the melengestrol acetate peak obtained from the Assay preparation; and rS is the average peak area of the melengestrol acetate peak obtained from the Standard preparation.
Auxiliary Information— Please check for your question in the FAQs before contacting USP.
Topic/Question Contact Expert Committee
Monograph Morgan Puderbaugh, B.S.
Associate Scientific Liaison
1-301-998-6833
(SM32010) Monographs - Small Molecules 3
Reference Standards RS Technical Services
1-301-816-8129
rstech@usp.org
USP35–NF30 Page 3788
Pharmacopeial Forum: Volume No. 30(3) Page 893