Ciclopirox
(sye'' kloe pir' ox).
2(1H)-Pyridinone, 6-cyclohexyl-1-hydroxy-4-methyl-. 6-Cyclohexyl-1-hydroxy-4-methyl-2(1H)-pyridone » Ciclopirox contains not less than 98.0 percent and not more than 101.0 percent of C12H17NO2, calculated on the dried basis.
Packaging and storage
Preserve in well-closed containers, protected from light. Store at a temperature between 15
Identification,
Infrared Absorption
Loss on drying
Residue on ignition
Heavy metals, Method II
Related compounds
[noteCarry out the operations avoiding exposure to actinic light. All materials in direct connection with Ciclopirox, like column materials, reagents, solvents, and others should contain only very low amounts of extractable metal cations. ]
Mobile phase
Prepare a filtered and degassed mixture of an edetate disodium solution (0.96 in 1000), acetonitrile, and glacial acetic acid (770:230:0.1). Make adjustments if necessary (see System Suitability under Chromatography
Rinsing solution
Prepare a mixture of water, acetonitrile, glacial acetic acid, and acetylacetone (500 : 500 : 1:1).
Standard stock solution
Dissolve USP Ciclopirox Related Compound A RS and USP Ciclopirox Related Compound B RS, accurately weighed, in an appropriate volume of acetonitrile and Mobile phase solution (approximate ratio, 1:7). Further dilute with Mobile phase to obtain a solution having a known final concentration of about 1.5 mg each per mL.
Standard solution A
Dilute 1.0 mL of Standard stock solution to 200.0 mL with a mixture of Mobile phase and acetonitrile (9:1).
Standard solution B
Dilute 2.0 mL of Standard solution A to 10.0 mL with a mixture of Mobile phase and acetonitrile (9:1).
Test solution
Dissolve 30 mg of Ciclopirox, accurately weighed, in a mixture of 2 mL of acetonitrile and 15 mL of Mobile phase. If necessary, use an ultrasonic bath. Dilute with Mobile phase to 20.0 mL.
Resolution solution
Mix 5 mL of Standard stock solution with 5 mL of the Test solution.
Chromatographic system (see Chromatography
Procedure
Separately inject equal volumes (about 10 µL) of Standard solution A, Standard solution B, and the Test solution into the chromatograph, and record the chromatograms. [noteIn order to ensure desorption of disruptive metal ions, every new column must be rinsed with the Rinsing solution over a period of not less than 15 hours and then with the Mobile phase for not less than 5 hours with a flow rate of 0.2 mL per minute. The chromatographic run time is not less than 2.5 times the retention time of the ciclopirox peak. ] The relative retention times are about 0.5 for ciclopirox related compound A, 0.9 for 6-cyclohexyl-4-methyl-2(1H)-pyridone, 1.0 for ciclopirox, and 1.3 for ciclopirox related compound B. The peak response at 220 nm of the ciclopirox related compound A peak in the chromatogram obtained from the Test solution is not more than the peak response at 220 nm of the corresponding peak in the chromatogram obtained from Standard solution A (0.5%). The sum of responses at 298 nm of the peaks in the chromatogram obtained from the Test solution is not more than the peak response at 298 nm of the ciclopirox related compound B peak in the chromatogram obtained from Standard solution A (0.5%). At 298 nm disregard any peak due to the solvent and any peak with a response less than the response of the ciclopirox related compound B peak in the chromatogram obtained from Standard solution B at 298 nm (0.1%).
Assay
Dissolve 150 mg of Ciclopirox, accurately weighed, in 20 mL of methanol. Add 20 mL of water, mix, and titrate with 0.1 N sodium hydroxide VS, determining the endpoint potentiometrically. Carry out a blank test. Determine the factor of the 0.1 N sodium hydroxide VS using 100 mg of benzoic acid, accurately weighed, and titrate under the conditions prescribed above. Each mL of 0.1 N sodium hydroxide is equivalent to 20.73 mg of C12H17NO2.