Tiamulin Fumarate
C28H47NO4S·C4H4O4
Tiamulin Hydrogen Fumarate. Acetic acid, [[2-(diethylaminoethyl]thio]-, 6-ethenyl-decahydro-5-hydroxy-4,6,9,10-tetramethyl-1-oxo-3a,9-propano-3aH-cyclopentacycloocten-8-yl ester [3aS-(3a [[2-(Diethylamino)ethyl]thio]acetic acid 8-ester with (3aS,4R,5S,6S,8R,9R,9aR,10R)-octahydro-5,8-dihydroxy-4,6,9,10-tetramethyl-6-vinyl-3a,9-propano-3aH-cyclopentacycloocten-1(4H)-one fumarate (1:1) (salt) » Tiamulin Fumarate contains not less than 97.0 percent and not more than 102.0 percent of C28H47NO4S·C4H4O4, calculated on the dried basis.
Packaging and storage
Preserve in tight, light-resistant containers, and store at room temperature.
Labeling
Label it to indicate that it is for veterinary use only.
Color and clarity of solution
Transfer about 5.0 g of Tiamulin Fumarate to a 100-mL volumetric flask, and dissolve in and dilute with water to volume: the solution is clear and colorless, and the absorbance of the solution, determined in a 1-cm cell at 400 and 650 nm, is not greater than 0.150 and 0.030 absorbance units, respectively.
Identification
A:
Infrared Absorption
B:
The retention time of the tiamulin fumarate peak in the chromatogram of the Assay preparation corresponds to that in the chromatogram of the Standard preparation, as obtained in the Assay.
Specific rotation
Test solution:
5.0 mg per mL, in dioxane.
pH
Test solution:
1.0 g per 100 mL of water.
Loss on drying
Residue on ignition
Heavy metals, Method II
Limit of residual solvents
Internal standard solution
Dilute 0.3 mL of n-butanol to 1000 mL.
Standard solution
Transfer about 500 mg each of acetone, ethyl acetate, and isobutyl acetate, each accurately weighed, to a 250-mL volumetric flask, dilute with the Internal standard solution to volume, and mix. Transfer 2.5 mL of the solution so obtained to a 20-mL volumetric flask, dilute with the Internal standard solution to volume, and mix.
Test solution
Transfer about 1 g of Tiamulin Fumarate, accurately weighed, to a 20-mL volumetric flask, dissolve in and dilute with the Internal standard solution to volume, and mix.
Chromatographic system (see Chromatography
Procedure
Separately inject equal volumes (about 1.0 µL) of the Standard solution and the Test solution into the chromatograph, record the chromatograms, and measure the peak responses for acetone, ethyl acetate, isobutyl acetate, and n-butanol. Calculate the percentages of acetone, ethyl acetate, and isobutyl acetate in the portion of Tiamulin Fumarate taken by the formula:
100(WS / WU)(RU / RS)
in which WS is the weight, in mg, of the solvent of interest taken to prepare the Standard solution; WU is the weight, in mg, of Tiamulin Fumarate taken to prepare the Test solution; and RU and RS are the peak response ratios of the solvent of interest to the internal standard obtained from the Test solution and the Standard solution, respectively: not more than 0.5% each of acetone, ethyl acetate, and isobutyl acetate is found; and the sum of the percentages of acetone, ethyl acetate, and isobutyl acetate is not more than 0.5%.
Chromatographic purity
Dilute perchloric acid solution, Buffer solution, Mobile phase, System suitability solution, and Chromatographic system
Proceed as directed in the Assay.
Standard solution
Use the Standard preparation prepared as directed in the Assay.
Test solution
Use the Assay preparation prepared as directed in the Assay.
Procedure
Separately inject equal volumes (about 20 µL) of the Standard solution and the Test solution into the chromatograph, record the chromatogram, identify the tiamulin fumarate peak, and measure all the peak responses. [notePossible tiamulin fumarate impurities include, but are not limited to, pleuromutilin, mutilin, 14-acetyl mutilin, 11-monoacetyl mutilin, tiamulin related compound A, 11,14-diacetyl mutilin, 8-dimethylderivative, bisdimethylthioderivative, and 11-ketoderivative, their retention times, relative to tiamulin fumarate, being about 0.25, 0.3, 0.5, 0.6, 0.8, 1.1, 1.3, 1.4, and 2.3, respectively.] Calculate the area percentage of each impurity, relative to tiamulin fumarate, in the portion of Tiamulin Fumarate taken by the formula:
100(ri / rU)
in which ri and rU are the peak responses of each impurity and tiamulin fumarate, respectively: not more than 1.0% of any identified impurity is found; not more than 0.5% of any unidentified impurity is found; and not more than 3.0% of total impurities is found.
Content of fumarate
Dissolve about 450 mg of Tiamulin Fumarate, accurately weighed, in 60 mL of a mixture of alcohol and water (1:1). Titrate with 0.1 N sodium hydroxide VS, determining the endpoint potentiometrically, using a glasscalomel electrode (see Titrimetry
Assay
Dilute perchloric acid solution
Prepare a solution containing 6% of perchloric acid.
Buffer solution
Transfer 10 g of ammonium carbonate to a 1000-mL volumetric flask, and dissolve in about 800 mL of water. Add 24 mL of Dilute perchloric acid solution, dilute with water to volume, mix, and filter.
Mobile phase
Prepare a mixture of methanol, Buffer solution, and acetonitrile, (49:28:23), filter, and degas.
System suitability solution
Dissolve accurately weighed quantities of USP Tiamulin Fumarate RS and USP Tiamulin Related Compound A RS in Mobile phase to obtain a solution having known concentrations of about 0.08 mg of each per mL.
Standard preparation
Dissolve an accurately weighed quantity of USP Tiamulin Fumarate RS in Mobile phase to obtain a solution having a known concentration of about 4 mg per mL.
Assay preparation
Transfer about 200 mg of Tiamulin Fumarate, accurately weighed, to a 50-mL volumetric flask, dissolve in and dilute with Mobile phase to volume, and mix.
Chromatographic system (see Chromatography
Procedure
Separately inject equal volumes (about 20 µL) of the Standard preparation and the Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of C28H47NO4S·C4H4O4 in the portion of Tiamulin Fumarate taken by the formula:
50C(rU / rS)
in which C is the concentration, in mg per mL, of USP Tiamulin Fumarate RS in the Standard preparation; and rU and rS are the tiamulin fumarate peak responses obtained from the Assay preparation and the Standard preparation, respectively.
Auxiliary Information
Please check for your question in the FAQs before contacting USP.
Chromatographic Column
USP32NF27 Page 3740
Pharmacopeial Forum: Volume No. 32(4) Page 1115
Chromatographic columns text is not derived from, and not part of, USP 32 or NF 27.
|