Technetium Tc 99m Gluceptate Injection
d-glycero-d-gulo-Heptonic acid, technetium-99mTc complex. Technetium-99mTc d-glycero-d-gulo-heptonate complex. » Technetium Tc 99m Gluceptate Injection is a sterile, aqueous solution, suitable for intravenous administration, of sodium gluceptate and stannous chloride that is labeled with 99mTc. It contains not less than 90.0 percent and not more than 110.0 percent of the labeled amount of 99mTc as stannous gluceptate complex expressed in megabecquerels (microcuries or millicuries) per mL at the time indicated in the labeling. It may contain antimicrobial agents and buffers. Other chemical forms of radioactivity do not exceed 10.0 percent of the total radioactivity.
Packaging and storage
Preserve in single-dose or in multiple-dose containers, at a temperature between 2
Labeling
Label it to include the following, in addition to the information specified for Labeling under Injections
Bacterial endotoxins
pH
Radiochemical purity
Place a measured volume of Injection, appropriately diluted, such that it provides a count rate of about 20,000 counts per minute, about 25 mm from one end of a 25- × 300-mm strip of chromatographic paper (see Chromatography
Biological distribution
Constitute 1 vial of Injection with 5 mL to 10 mL of Sodium Pertechnetate Tc 99m Injection. Inject intravenously 0.25 mL of the resulting undiluted Injection into the caudal vein of each of three 150- to 250-g rats. Discard any injections in which extravasation occurs. Approximately 1 hour after the injection, anesthetize the animals and exsanguinate, collecting the blood into a suitable container. Dissect the animals, and place the kidneys, liver, gastrointestinal tract, and a specimen of blood, accurately weighed, in separate, suitable counting containers, and determine the radioactivity, in counts per minute, in each container with an appropriate detector using the same counting geometry. Determine the percentage of radioactivity in the kidneys, liver, and gastrointestinal tract taken by the formula:
100Ai / A
in which Ai is the net radioactivity in the organ, and A is the total radioactivity, in MBq (µCi), injected, both corrected to injection time. Determine the percentage of radioactivity in the blood taken by the formula:
[100(B/WS)0.07(WR)]/A
in which B is the net radioactivity in the specimen of blood, and A is the total radioactivity, injected, both corrected to injection time, WS is the weight, in g, of the blood specimen, WR is the weight, in g, of the rat, and 0.07 is the assumption that the total blood weight of the rat is 7% of the total body weight. Not less than 15.0% of the radioactivity is found in the kidneys, not more than 5.0% of the radioactivity is found in the blood, not more than 15.0% of the radioactivity is found in the entire gastrointestinal tract and not more than 5.0% of the radioactivity is found in the liver, in not fewer than 2 of the rats.
Other requirements
It meets the requirements for Radionuclide identification and Radionuclidic purity under Sodium Pertechnetate Tc 99m Injection. It meets also the requirements under Injections
Assay for radioactivity
Auxiliary Information
Please check for your question in the FAQs before contacting USP.
USP32NF27 Page 3663
|