Meropenem
Click to View Image
C17H25N3O5S·3H2O 437.52
1-Azabicyclo[3.2.0]hept-2-ene-2-carboxylic acid, 3-[[5-[(dimethylamino)carbonyl]-3-pyrrolidinyl]thio]-6-(1-hydroxyethyl)-4-methyl-7-oxo, trihydrate, [4R-[3(3S*,5S*),4,5,6(R*)]]-.
(4R,5S,6S)-3-[[(3S,5S)-5-(Dimethylcarbamoyl)-3-pyrrolidinyl]thio]-6-[(1R)-1-hydroxyethyl]-4-methyl-7-oxo-1-azabicyclo[3.2.0]hept-2-ene-carboxylic acid, trihydrate [119478-56-7].

Anhydrous 383.47 [96036-03-2].
» Meropenem contains not less than 98.0 percent and not more than 101.0 percent of C17H25N3O5S, calculated on the anhydrous basis.
Packaging and storage— Preserve in tight containers. Store the dry powder at controlled room temperature.
Labeling— Where it is intended for use in preparing injectable dosage forms, the label states that it is sterile or must be subjected to further processing during the preparation of injectable dosage forms.
USP Reference standards 11
USP Endotoxin RS
.
USP Meropenem RS
.
Identification—
B: Ultraviolet Absorption 197U
Solution: 30 µg per mL.
Medium: water.
Specific rotation 781: between 17 and 21, measured at 20.
Test solution: 5 mg per mL, in water.
pH 791: between 4.0 and 6.0, in a solution (1 in 100).
Water, Method Ic 921: between 11.4% and 13.4%.
Residue on ignition 281: not more than 0.1%, igniting at 500 ± 50, instead of at 800 ± 25. Use a desiccator containing silica gel.
Heavy metals—
Sodium sulfide reagent— Dissolve 5 g of sodium sulfide in a mixture of 10 mL of water and 30 mL of glycerin. Preserve in well-filled, light-resistant bottles, and use within 3 months.
Test solution— Transfer 1.0 g of Meropenem to a quartz or porcelain crucible, cover loosely with a lid, and carbonize by gentle ignition. After cooling, add 2 mL of nitric acid and 5 drops of sulfuric acid, heat cautiously until white fumes evolve, and incinerate by ignition at 500 to 600. Cool, add 2 mL of hydrochloric acid, and evaporate on a water bath to dryness. Moisten the residue with 3 drops of hydrochloric acid, add 10 mL of hot water, and warm for 2 minutes. Add 1 drop of phenolphthalein TS, add ammonia TS, dropwise, until the solution develops a pale red color, and add 2 mL of 1 N acetic acid. Filter, if necessary, to obtain a clear solution, washing the filter with 10 mL of water. Transfer the filtrate and the washing to a 50-mL color-comparison tube, and add water to obtain a volume of 50 mL.
Standard solution— Evaporate a mixture of 2 mL of nitric acid, 5 drops of sulfuric acid, and 2 mL of hydrochloric acid on a water bath, further evaporate to dryness on a hot sand bath, and moisten the residue with 3 drops of hydrochloric acid. Proceed as directed for Test solution, beginning with “add 10 mL of hot water,” except add water to obtain a volume of 49 mL. Add 1.0 mL of Standard Lead Solution (see Heavy Metals 231).
Procedure— To the tubes containing the Test solution and the Standard solution, add 1 drop of Sodium sulfide reagent, mix, and allow to stand for 5 minutes. The color in the tube containing the Test solution is not darker than the color in the tube containing the Standard solution (0.001%).
Limit of acetone—
Internal standard solution— Prepare a solution in dimethylformamide containing 0.05 µL of ethyl acetate per mL.
Standard solution— Transfer about 50 mg of acetone, accurately weighed, to a 100-mL volumetric flask, dilute with dimethylformamide to volume, and mix. To 1.0 mL of this solution, add 10.0 mL of the Internal standard solution, and mix.
Test solution— Dissolve 100 mg of Meropenem, accurately weighed, in 0.2 mL of dimethylformamide and 2.0 mL of Internal standard solution.
Chromatographic system (see Chromatography 621)— The gas chromatograph is equipped with a flame-ionization detector and a 3-mm × 2-m column that contains support S2 and is maintained at a constant temperature of about 150. The injection port temperature is maintained at about 170. Nitrogen is the carrier gas, with the flow rate adjusted so that the retention time for acetone is about 3 minutes.
Procedure— Separately inject equal volumes (about 2 µL) of the Standard solution and the Test solution into the chromatograph, record the chromatograms, and measure the peak responses for the acetone peak and the internal standard peak. Calculate the percentage of acetone in the portion of Meropenem taken by the formula:
(WA/5WU)(RU / RS)
in which WA is the weight, in mg, of acetone in the Standard solution; WU is the quantity, in mg, of Meropenem in the Test solution; and RU and RS are the peak area ratios of acetone to the internal standard obtained from the Test Solution and the Standard solution, respectively. Not more than 0.05% is found.
Chromatographic purity—
Diluted phosphoric acid— Dilute 10 mL of phosphoric acid with water to make 100 mL of solution.
Solvent— Transfer 1.0 mL of triethylamine to a 1000-mL volumetric flask containing 900 mL of water. Adjust with Diluted phosphoric acid to a pH of 5.0 ± 0.1, dilute with water to volume, and mix.
Mobile phase— Transfer 1.0 mL of triethylamine to a 1000-mL volumetric flask containing 900 mL of water. Adjust with Diluted phosphoric acid to a pH of 5.0 ± 0.1, dilute with water to volume, and mix. Mix this solution with 70 mL of acetonitrile. Make adjustments if necessary (see System Suitability under Chromatography 621).
Standard solution— Prepare a solution of USP Meropenem RS in Solvent having a known concentration of about 0.025 mg of USP Meropenem RS per mL. [note—Immediately after preparation, store this solution in a refrigerator and use within 24 hours.]
Test solution— Dissolve an accurately weighed quantity of Meropenem quantitatively in Solvent to obtain a solution having a known concentration of about 5 mg per mL. Use this Test solution immediately.
Chromatographic system (see Chromatography 621)— The liquid chromatograph is equipped with a 220-nm detector and a 4.6-mm × 25-cm column that contains 5-µm packing L1 and is maintained at a constant temperature of about 40. The flow rate is about 1.6 mL per minute, and is adjusted so that the retention time of meropenem is between 5 and 7 minutes. Chromatograph the Standard solution, and record the peak responses as directed for Procedure: the column efficiency is not less than 2500 theoretical plates; the tailing factor is not more than 1.5; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure— Separately inject equal volumes (about 10 µL) of the Standard solution and the Test solution into the chromatograph, record the chromatograms, using a period of chromatography for the Test solution that is about 3 times the retention time of meropenem, and measure the peak responses. Major impurity peaks may be observed at retention times of about 0.45 and 1.9 in relation to the retention time of meropenem. Calculate the percentage of each impurity in the chromatogram obtained from the Test solution by the formula:
(CS / CU)(P)(ri / rS)
in which CS is the concentration, in mg per mL, of USP Meropenem RS in the Standard solution; CU is the concentration, in mg per mL, of Meropenem in the Test solution; P is the stated percentage, calculated on the anhydrous basis, of meropenem in USP Meropenem RS; ri is the peak response of any individual impurity obtained from the Test solution; and rS is the peak response of meropenem obtained from the Standard solution. Not more than 0.3% of any of two major impurities is found, calculated on the anhydrous basis; not more than 0.1% of any other impurity is found, calculated on the anhydrous basis; and the sum of all such other impurities is not more 0.3%.
Other requirements— Where the label states that Meropenem is sterile, it meets the requirements for Sterility 71 and for Bacterial endotoxins under Meropenem for Injection. Where the label states that Meropenem must be subjected to further processing during the preparation of injectable dosage forms, it meets the requirements for Bacterial endotoxins under Meropenem for Injection.
Assay—
Diluted phosphoric acid— Dilute 10 mL of phosphoric acid with water to make 100 mL of solution.
Solvent— Transfer 1.0 mL of triethylamine to a 1000-mL volumetric flask containing 900 mL of water. Adjust with Diluted phosphoric acid to a pH of 5.0 ± 0.1, dilute with water to volume, and mix.
Mobile phase— Prepare a mixture of Solvent and methanol (5:1). Make adjustments if necessary (see System Suitability under Chromatography 621).
Standard preparation— Transfer about 25 mg of USP Meropenem RS, accurately weighed, to a 50-mL volumetric flask, add Solvent, swirl to dissolve, dilute with Solvent to volume, and mix. [note—Immediately after preparation, store this solution in a refrigerator. It may be used for 24 hours.]
Assay preparation— Transfer about 25 mg of Meropenem, accurately weighed, to a 50-mL volumetric flask, add Solvent, swirl to dissolve, dilute with Solvent to volume, and mix. Use this solution immediately after preparation.
Chromatographic system (see Chromatography 621)— The liquid chromatograph is equipped with a 300-nm detector and a 4.6-mm × 25-cm column that contains 5-µm packing L1. Adjust the flow rate so that the retention time for meropenem is about 6 to 8 minutes. The flow rate is about 1.5 mL per minute. Chromatograph the Standard preparation, and record the peak responses as directed for Procedure: the column efficiency is not less than 2500 theoretical plates; the tailing factor is not more than 1.5; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure— Separately inject equal volumes (about 5 µL) of Standard preparation and Assay preparation into the chromatograph, record the chromatograms, and measure the areas for the major peaks. Calculate the quantity, in mg, of C17H25N3O5S in the portion of Meropenem taken by the formula:
(WS/WU)(P)(rU / rS)
in which WS is the weight, in mg, of USP Meropenem RS taken to prepare the Standard preparation, calculated on the anhydrous basis; WU is the weight, in mg, of Meropenem taken to prepare the Assay preparation; P is the stated percentage, calculated on the anhydrous basis, of meropenem in USP Meropenem RS; and rU and rS are the meropenem peak responses obtained from the Assay preparation and the Standard preparation, respectively.
Auxiliary Information— Please check for your question in the FAQs before contacting USP.
Topic/Question Contact Expert Committee
Monograph Ahalya Wise, M.S.
Scientist
1-301-816-8161
(MDANT05) Monograph Development-Antibiotics
Reference Standards Lili Wang, Technical Services Scientist
1-301-816-8129
RSTech@usp.org
USP32–NF27 Page 2891
Pharmacopeial Forum: Volume No. 27(1) Page 1801
Chromatographic Column—
Chromatographic columns text is not derived from, and not part of, USP 32 or NF 27.