Flurandrenolide Tape
» Flurandrenolide Tape is a nonporous, pliable, adhesive-type tape having Flurandrenolide impregnated in the adhesive material, the adhesive material on one side being transported on a removable, protective slit-paper liner. Flurandrenolide Tape contains not less than 80.0 percent and not more than 125.0 percent of the labeled amount of C24H33FO6.
Packaging and storage— Preserve at controlled room temperature.
Identification— Extract a portion of Tape, equivalent to about 200 µg of flurandrenolide, as directed for the Assay preparation in the Assay. Omit the addition of the internal standard, and evaporate the chloroform extracts on a steam bath under a stream of nitrogen to about 3 mL. Transfer the chloroform solution to a 10-mL flask, and evaporate with the aid of a stream of nitrogen to dryness. Dissolve the residue in 1.0 mL of a mixture of equal volumes of chloroform and methanol, warming gently to effect solution: it meets the requirements of the Thin-Layer Chromatographic Identification Test 201, 5 µL each of the test solution and Standard solution being applied, and the solvent mixture consisting of ethyl acetate and ether (70:30).
Microbial enumeration tests 61 and Tests for specified microorganisms 62 It meets the requirements of the tests for absence of Staphylococcus aureus and Pseudomonas aeruginosa.
Assay—
Methanolic sodium chloride, Mobile phase, and Chromatographic system— Prepare as directed in the Assay under Flurandrenolide Cream.
Flurandrenolide standard solution— Dissolve about 7 mg of USP Flurandrenolide RS, accurately weighed, in 50 mL of methanol in a 100-mL volumetric flask. Dilute with methanol to volume, and mix.
Internal standard solution— Dissolve about 4 mg of Testosterone in 50 mL of methanol in a 100-mL volumetric flask. Dilute with methanol to volume, and mix.
Standard preparation— Pipet 3.0 mL of Flurandrenolide standard solution and 4.0 mL of Internal standard solution into a 10-mL volumetric flask. Dilute with water to volume, and mix.
Assay preparation— Accurately measure and cut a portion of Tape, equivalent to about 200 µg of flurandrenolide. Remove and discard the paper liner from the portion of Tape. Touch the flattened end of a glass rod to the adhesive side of the Tape, and carefully transfer the tape to the bottom of a 600-mL beaker containing 15 mL of anhydrous methanol, taking care that the adhesive side of the tape does not adhere to the wall of the beaker. Remove the glass rod from the tape, and wash it with 5 mL of anhydrous methanol, adding the wash to the beaker. Place the beaker containing the Tape and the methanol in an ultrasonic bath for 3 minutes, rotating the beaker in such manner that the methanol is in contact with all portions of the Tape. Transfer the methanol to a 250-mL separator. Extract the Tape, using sonication, with two additional 20-mL portions of anhydrous methanol, adding each portion to the separator. To the combined methanol extract add 15 mL of sodium chloride solution (1 in 10) and 50 mL of hexane, and shake vigorously. Allow the phases to separate, and drain the lower aqueous phase into a second separator containing 15 mL of hexane. Shake vigorously, allow the phases to separate, and drain the lower phase into a third 250-mL separator containing 100 mL of water. Serially extract the hexane phases remaining in the two separators with one 25-mL portion of Methanolic sodium chloride, adding the extract to the third separator. Discard the hexane phases. Extract the combined aqueous phases with four 25-mL portions of chloroform. Filter each chloroform extract through 10 g of anhydrous sodium sulfate into a 125-mL conical beaker. Rinse the sodium sulfate with water-washed chloroform, and add the wash to the beaker. Add 4.0 mL of Internal standard solution to the beaker. Evaporate the solution on a steam bath under a stream of nitrogen to near dryness. Remove the beaker from the steam bath and evaporate the remaining solution with the aid of nitrogen to dryness. Add 10 mL of Mobile solvent to the beaker, and place it in an ultrasonic bath to dissolve the residue. Pass the solution through a suitable porosity filter having a 0.5-µm filter with a prefilter above the membrane filter to prevent clogging.
Procedure— Separately inject equal volumes (about 50 µL) of the Standard preparation and the Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. The relative retention times are about 2 for testosterone and 1.0 for flurandrenolide. Calculate the quantity, in µg, of C24H33FO6 in the portion of Tape taken by the formula:
10C(RU / RS)
in which C is the concentration, in µg per mL, of USP Flurandrenolide RS in the Standard preparation; and RU and RS are the peak response ratios obtained from the Assay preparation and the Standard preparation, respectively.
Auxiliary Information— Please check for your question in the FAQs before contacting USP.
Topic/Question Contact Expert Committee
Monograph Daniel K. Bempong, Ph.D.
Senior Scientist
1-301-816-8143
(MDPS05) Monograph Development-Pulmonary and Steroids
Reference Standards Lili Wang, Technical Services Scientist
1-301-816-8129
RSTech@usp.org
61 Radhakrishna S Tirumalai, Ph.D.
Senior Scientist
1-301-816-8339
(MSA05) Microbiology and Sterility Assurance
62 Radhakrishna S Tirumalai, Ph.D.
Senior Scientist
1-301-816-8339
(MSA05) Microbiology and Sterility Assurance
USP32–NF27 Page 2427
Chromatographic Column—
Chromatographic columns text is not derived from, and not part of, USP 32 or NF 27.