Add the following:
Fenofibrate Capsules
» Fenofibrate Capsules contain not less than 90.0 percent and not more than 110.0 percent of the labeled amount of fenofibrate (C20H21ClO4).
Packaging and storage— Preserve in well-closed containers, and store at controlled room temperature.
Labeling— When more than one Dissolution test is given, the labeling states the test used only if Test 1 is not used.
Identification—
A: Infrared Absorption 197K
Test specimen— Transfer the contents of 1 Capsule to a glass centrifuge tube, add an amount of methylene chloride, equivalent to about 10 mL per 67 mg of fenofibrate, and shake vigorously. Pass through a suitable paper filter into a separatory funnel, wash with water, and collect the methylene chloride layer. Evaporate under a stream of nitrogen, and dry under vacuum at 60 for 1 hour. Mix about 4 mg of the dried sample with about 200 mg of potassium bromide.
B: The retention time of the major peak in the chromatogram of the Assay preparation corresponds to that in the chromatogram of the Standard preparation, as obtained in the Assay.
Dissolution 711
test 1—
Medium: 0.05 M sodium lauryl sulfate in water; 1000 mL, deaerated.
Apparatus 2: 75 rpm.
Time: 40 minutes.
Buffer solution pH 2.9 and Mobile phase— Prepare as directed in the Assay.
Standard solution— Dissolve an accurately weighed quantity of USP Fenofibrate RS in Mobile phase to obtain a solution having a known concentration of about (0.001 × L) mg per mL, where L is the Capsule label claim, in mg.
Test solution— Filter a portion of the solution under test through a 0.45-µm polyvinylidene difluoride (PVDF) filter.
Chromatographic system (see Chromatography 621)—Prepare as directed in the Assay. Chromatograph the Standard solution, and record the peak responses as directed for Procedure: the column efficiency is not less than 4000 theoretical plates; the tailing factor is not more than 2.0; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure— Separately inject equal volumes (about 10 µL for Capsules labeled to contain 67 mg and about 5 µL for Capsules labeled to contain 134 mg or 200 mg) of the Standard solution and the Test solution into the chromatograph, record the chromatograms, and measure the peak responses. Calculate the amount of C20H21ClO4 dissolved by the formula:
Click to View Image
in which rU and rS are the peak responses for the Test solution and the Standard solution, respectively; CS is the concentration, in mg per mL, of the Standard solution; 1000 is the volume, in mL, of Medium; 100 is the conversion factor to percentage; and L is the Capsule label claim, in mg.
Tolerances— Not less than 70% (Q) of the labeled amount of C20H21ClO4 is dissolved in 40 minutes.
test 2— If the product complies with this test, the labeling indicates that the product meets USP Dissolution Test 2.
Medium: phosphate buffer pH 6.8 ± 0.1 containing 0.1% pancreatin and 2% polysorbate 80; 900 mL, deaerated with vacuum.
Apparatus 2: 75 rpm, with sinker (see Dissolution 711, Figure 2a).
Time: 120 minutes.
Standard solution— Prepare solutions of USP Fenofibrate RS in Medium to obtain a final concentration of L/1000 mg per mL, where L is the Capsule label claim. A volume of methanol, not exceeding 10%, can be used in the first dilution to solubilize fenofibrate.
Test solution— Pass 20 mL of the solution under test through a 0.45-µm PVDF filter, discarding the first 2 mL.
Procedure— Determine the amount of fenofibrate (C20H21ClO4) dissolved by employing UV absorption at the wavelength of maximum absorbance at about 288 nm on the Test solution in comparison with the appropriate Standard solution, using Medium as the blank and a 0.1-cm flow cell. Calculate the amount of fenofibrate (C20H21ClO4), in percentage, dissolved by the formula:
Click to View Image
in which AU and AS are the absorbances obtained from the Test solution and the appropriate Standard solution, respectively; CS is the concentration of fenofibrate in the appropriate Standard solution; 900 is the volume, in mL, of Medium; 100 is the conversion factor to percentage; and L is the Capsule label claim, in mg.
Tolerances— Not less than 80% (Q) of the labeled amount of C20H21ClO4 is dissolved in 120 minutes.
Uniformity of dosage units 905: meet the requirements.
procedure for content uniformity—
Buffer solution pH 2.9, Mobile phase, Standard preparation, and Chromatographic system— Proceed as directed in the Assay.
Test solution— Place 1 Capsule in a suitable volumetric flask, add Buffer solution pH 2.9 to 10% to 20% of the final volume, and stir for 20 minutes to disintegrate the Capsule. Fill the flask to about 80% with methanol, sonicate for 10 minutes, stir for 15 minutes, and dilute with methanol to volume to obtain a solution having a known concentration of about 0.4 to 0.7 mg of fenofibrate per mL, based on the label claim. Quantitatively dilute an aliquot with Mobile phase, to obtain a solution having a known concentration of about 0.06 to 0.07 mg per mL, and pass it through a 0.45-um PVDF filter, discarding the first 5 mL.
Procedure— Proceed as directed in the Assay, except to inject the Test solution instead of the Assay preparation.
Related compounds—
Buffer solution pH 2.9 and Mobile phase— Prepare as directed in the Assay.
System suitability solution— Dissolve an accurately weighed quantity of USP Fenofibrate RS and USP Fenofibrate Related Compound B RS in Mobile phase to obtain a solution having concentrations of about 0.67 mg per mL and 3.35 µg per mL, respectively. [Note—Fenofibrate related compound B is 2-[4-(4-chlorobenzoyl)phenoxy]-2-methylpropanoic acid (fenofibric acid).]
Standard solution— Dissolve an accurately weighed quantity of USP Fenofibrate RS and USP Fenofibrate Related Compound B RS in Mobile phase to obtain a solution having known concentrations of about 3.35 µg per mL of each component.
Sensitivity solution— Quantitatively dilute an aliquot of the Standard solution with Mobile phase, to obtain a solution having concentrations of about 0.67 µg of each component per mL.
Test solution— Accurately weigh the contents of not fewer than 20 Capsules. Mix the contents, and transfer an accurately weighed portion of the powder, equivalent to about 67 mg of fenofibrate, to a 100-mL volumetric flask. Fill the flask to about 80% with Mobile phase, sonicate for 10 minutes, stir for 15 minutes, and dilute with Mobile phase to volume. Pass a portion of this solution through a 0.45-µm PVDF filter, discarding the first 5 mL. The final concentration is about 0.67 mg per mL.
Chromatographic system (see Chromatography 621) Prepare as directed in the Assay. Chromatograph the System suitability solution, and record the peak responses as directed for Procedure: the resolution, R, between fenofibrate and fenofibrate related compound B is not less than 3.0; the column efficiency for the fenofibrate related compound B peak is not less than 3000 theoretical plates; and the tailing factor is not more than 2.0. Chromatograph the Sensitivity solution, and record the peak responses as directed for Procedure: the signal-to-noise ratio is not less than 10 for the fenofibrate peak. Chromatograph the Standard solution, and record the peak responses as directed for Procedure: the relative standard deviation for replicate injections is not more than 2.0% for each peak.
Procedure— Separately inject equal volumes (about 20 µL) of the Standard solution and the Test solution into the chromatograph, record the chromatograms, and measure the peak responses. Calculate the percentage of fenofibrate related compound B relative to the fenofibrate labeled content in the portion of Capsules taken by the formula:
100(CS / CT)(ri / rS)
in which CS is the concentration, in mg per mL, of fenofibrate related compound B in the Standard solution; CT is the concentration, in mg per mL, of fenofibrate in the Test solution, based on the label claim; and ri and rS are the responses of fenofibrate related compound B obtained from the Test solution and the Standard solution, respectively. Calculate the percentage of any other impurity relative to the fenofibrate labeled content in the portion of Capsules taken by the formula:
100(CF / CT)(ri / rF)
in which CF is the concentration, in mg per mL, of fenofibrate in the Standard solution; CT is as defined above; ri is the peak response of each impurity obtained from the Test solution; and rF is the peak response of the fenofibrate, obtained from the Standard solution. Not more than 0.5% of fenofibrate related compound B is found; not more than 0.2% of any other impurity is found; and not more than 2.0% of total impurities is found.
Assay—
Buffer solution pH 2.9— Dissolve 136 g of monobasic potassium phosphate in 1000 mL of water, and adjust with dilute phosphoric acid (1 in 10) to a pH of 2.9 ± 0.05.
Mobile phase— Prepare a mixture of methanol and Buffer solution pH 2.9 (80:20). Make adjustments if necessary (see System Suitability under Chromatography 621).
Standard preparation— Dissolve an accurately weighed quantity of USP Fenofibrate RS in Mobile phase to obtain a solution having a known concentration of about 0.067 mg per mL.
Assay preparation— Accurately weigh the contents of not fewer than 20 Capsules. Mix the contents, and transfer an accurately weighed portion of the powder, equivalent to about 67 mg of fenofibrate, to a 100-mL volumetric flask. Fill the flask to about 80% with Mobile phase, sonicate for 10 minutes, stir for 15 minutes, and dilute with Mobile phase to volume. Quantitatively dilute 5.0 mL of this solution to 50 mL with Mobile phase, and pass a portion of this solution through a 0.45-µm PVDF filter, discarding the first 5 mL. The final concentration based on the label claim is about 0.067 mg per mL.
Chromatographic system (see Chromatography 621) The liquid chromatograph is equipped with a 285-nm detector and a 4.6-mm × 15-cm column that contains 5-µm packing L1. The flow rate is about 1.0 mL per minute. Chromatograph the Standard preparation, and record the peak responses as directed for Procedure: the column efficiency is not less than 6000 theoretical plates; the tailing factor is not more than 2.0; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure— Separately inject equal volumes (about 20 µL) of the Standard preparation and the Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the percentage of the labeled amount of fenofibrate (C20H21ClO4) in the portion of Capsules taken by the formula:
100(CS / CU)(rU / rS)
in which CS is the concentration, in mg per mL, of fenofibrate in the Standard preparation; CU is the concentration, in mg per mL, of fenofibrate in the Assay preparation, based on the label claim; and rU and rS are the peak areas obtained from the Assay preparation and the Standard preparation, respectively.USP32
Auxiliary Information— Please check for your question in the FAQs before contacting USP.
Topic/Question Contact Expert Committee
Monograph Elena Gonikberg, Ph.D.
Senior Scientist
1-301-816-8251
(MDGRE05) Monograph Development-Gastrointestinal Renal and Endocrine
Reference Standards Lili Wang, Technical Services Scientist
1-301-816-8129
RSTech@usp.org
711 Margareth R.C. Marques, Ph.D.
Senior Scientist
1-301-816-8106
(BPC05) Biopharmaceutics05
USP32–NF27 Page 2352
Pharmacopeial Forum: Volume No. 34(2) Page 258
Chromatographic Column—
Chromatographic columns text is not derived from, and not part of, USP 32 or NF 27.