Iobenguane I 131 Injection
[[3-(Iodo-131I)-phenyl]methyl]guanidine sulfate (2:1). [(m-Iodo-131I)-benzyl]guanidine sulfate (2:1). » Iobenguane I 131 Injection is a sterile solution containing iobenguane sulfate in which a portion of the molecules contain radioactive iodine (131I) in the molecular structure. Iobenguane I 131 Injection contains not less than 90.0 percent and not more than 110.0 percent of the labeled amount of 131I as iobenguane sulfate expressed in megabecquerels (or in millicuries) per mL at the time indicated in the labeling. It may contain preservatives or stabilizers.
Packaging and storage
Preserve in single-dose or in multiple-dose containers that are adequately shielded. Store in a freezer.
Labeling
Label it to include the following: the date of calibration; the amount of 131I as iobenguane sulfate expressed as total megabecquerels (or millicuries) per mL at the time of calibration; the name and quantity of any added preservative or stabilizer; the expiration date; and the statement, CautionRadioactive Material. The labeling indicates that, in making dosage calculations, correction is to be made for radioactive decay, and also indicates that the radioactive half-life of 131I is 8.04 days.
Radionuclidic identification (see Radioactivity
Bacterial endotoxins
pH
Radionuclidic purity
Using a suitable counting assembly (see Selection of a Counting Assembly under Radioactivity
Radiochemical purity
Mobile phase
Prepare a filtered and degassed mixture of water and acetonitrile (900:100). Add 3.04 g of triethylamine per liter, and adjust with phosphoric acid to a pH of 4.0 ± 0.4. Make adjustments if necessary (see System Suitability under Chromatography
Standard preparation
Dissolve an accurately weighed quantity of iobenguane sulfate in water to obtain a solution having a known concentration of about 1 mg per mL.
Test preparation
Use Iobenguane I 131 Injection.
Chromatographic system
(see Chromatography
Procedure
Inject a volume (about 20 µL) of Injection, equivalent to between 1.6 and 2.7 MBq (or between 44 and 64 µCi) into the chromatograph, record the chromatograms, and measure the areas for the major peaks. The radioactivity of the iobenguane 131I peak is not less than 90% of the total radioactivity measured, and its retention time is within 10% of that of the Standard preparation, similarly chromatographed. The retention time of the iobenguane 131I peak obtained from the Injection is also within 10% of that obtained from the Standard preparation.
Other requirements
It meets the requirements under Injections
Assay for radioactivity
Using a counting assembly (see Selection of a Counting Assembly under Radioactivity
Auxiliary Information