Technetium Tc 99m Pyrophosphate Injection
» Technetium Tc 99m Pyrophosphate Injection is a sterile, aqueous solution, suitable for intravenous administration, of pyrophosphate that is labeled with 99mTc. It contains not less than 90.0 percent and not more than 110.0 percent of the labeled amount of 99mTc as pyrophosphate expressed in megabecquerels (microcuries or millicuries) per mL at the time indicated in the labeling. It may contain antimicrobial agents, buffers, reducing agents, and stabilizers. Other chemical forms of radioactivity do not exceed 10.0 percent of the total radioactivity.
Packaging and storage
Preserve in single-dose or multiple-dose containers, at a temperature between 2
Labeling
Label it to include the following, in addition to the information specified for Labeling under Injections
Bacterial endotoxins
pH
Radiochemical purity
The determination of radiochemical purity for this product requires the use of two separate chromatography systems.
System A
Under an atmosphere of nitrogen, place a measured volume of Injection, appropriately diluted, such that it provides a count rate of about 20,000 counts per minute, about 20 mm from one end of a thin-layer chromatographic strip impregnated with silica gel (see Chromatography
System B
Proceed as directed for System A, except to develop the chromatogram in a mixture of methanol and acetone (1:1). Free pertechnetate is located at the solvent front. The sum of the percentage of radioactivity at the origin in System A plus the percentage of radioactivity at the solvent front in System B is not greater than 10.0%.
Biological distribution
Inject intravenously between 0.075 MBq and 75 MBq (2 µCi and 2 mCi) of Injection, in a volume not exceeding 0.2 mL, into the caudal or external jugular vein of each of three 175- to 250-g rats. Approximately 1 hour after the injection, sacrifice the animals, and carefully remove the liver, both kidneys, and one femur of each by dissection, freeing the femur from soft tissue. Remove the tail 20 to 30 mm above the injection site, and discard. Place each organ, both kidneys, and the remaining carcass in separate, suitable counting containers, and determine the radioactivity, in counts per minute, in each container with an appropriate detector, using the same counting geometry. Determine the percentage of radioactivity in the liver, kidneys, and femur taken by the formula:
100(A / B)
in which A is the net radioactivity, in counts per minute, in the organ, and B is the total radioactivity, in counts per minute, in the liver, kidneys, femur, and carcass. Not more than 5.0% of the total radioactivity is found in the liver or in the kidneys, and not less than 1.0% of the total radioactivity is found in the femur, in not fewer than 2 of the rats.
Other requirements
It meets the requirements of the tests for Radionuclide identification and Radionuclidic purity under Sodium Pertechnetate Tc 99m Injection. It meets also the requirements under Injections
Assay for radioactivity
Auxiliary Information
Please check for your question in the FAQs before contacting USP.
USP32NF27 Page 3670
|