Multiple Electrolytes and Invert Sugar Injection Type 2
» Multiple Electrolytes and Invert Sugar Injection Type 2 is a sterile solution of a mixture of equal amounts of Dextrose and Fructose, or an equivalent solution produced by the hydrolysis of Sucrose, and suitable salts in Water for Injection to provide sodium, potassium, magnesium, calcium, chloride, and lactate ions. It contains not less than 90.0 percent and not more than 110.0 percent of the labeled amounts of sodium (Na), potassium (K), magnesium (Mg), calcium (Ca), lactate (C3H5O3), and invert sugar (C6H12O6), and not less than 90.0 percent and not more than 120.0 percent of the labeled amount of chloride (Cl). It may contain Hydrochloric Acid or Sodium Hydroxide used to adjust the pH. It contains no antimicrobial agents.
Packaging and storage— Preserve in single-dose glass or plastic containers. Glass containers are preferably of Type I or Type II glass.
Labeling— The label states the content of each electrolyte in terms of milliequivalents in a given volume. The label states the total osmolar concentration in mOsmol per L. When the contents are less than 100 mL, the label alternatively may state the total osmolar concentration in mOsmol per mL.
USP Reference standards 11
USP Sodium Lactate RS Click to View Structure
Identification—
A: It responds to the Identification test under Invert Sugar Injection.
B: It responds to the flame tests for Sodium 191 and Potassium 191, to the tests for Magnesium 191 and Chloride 191, and to the oxalate test for Calcium 191.
C: The retention time of the lactate peak in the chromatogram of the Assay preparation corresponds to that of the Standard preparation obtained as directed in the Assay for lactate.
Pyrogen— It meets the requirements of the Pyrogen Test 151. [note—Dilute, with Water for Injection, Injection containing more than 10% of invert sugar to give a concentration of 10% invert sugar. ]
pH 791: between 4.5 and 6.0.
Completeness of inversion—
Mobile phase, Standard preparation, and Chromatographic system— Prepare as directed in the test for Completeness of inversion under Invert Sugar Injection.
Test preparation— Transfer an accurately measured volume of Injection, equivalent to about 2.5 g of invert sugar, to a 100-mL volumetric flask, dilute with water to volume, and mix.
Procedure— Proceed as directed for Procedure in the test for Completeness of inversion under Invert Sugar Injection. Calculate the quantity, in mg, of sucrose in the volume of Injection taken by the formula:
100C(rU / rS)
in which the terms are as defined therein. Not more than 1.5% of the quantity of invert sugar in the volume of Injection taken, based on the labeled amount, is found.
Other requirements— It meets the requirements under Injections 1.
Assay for potassium and sodium—
Internal standard solution, Potassium stock solution, Sodium stock solution, Stock standard preparation, and Standard preparation— Prepare as directed in the Assay for potassium and sodium under Potassium Chloride in Sodium Chloride Injection.
Assay preparation— Transfer 5.0 mL of Injection to a 500-mL volumetric flask, dilute with Internal standard solution to volume, and mix.
Procedure— Proceed as directed for Procedure in the Assay for potassium and sodium under Potassium Chloride in Sodium Chloride Injection. Calculate the quantity, in mg, of potassium (K) in each mL of the Injection taken by the formula:
C(RU,766 / RU,671)(RS,671 / RS,766)
in which the terms are as defined therein. Each mg of potassium is equivalent to 0.02558 mEq of potassium. Calculate the quantity, in mg, of sodium (Na) in each mL of the Injection taken by the formula:
C(RU,589 / RU,671)(RS,671 / RS,589)
in which the terms are as defined therein. Each mg of sodium is equivalent to 0.04350 mEq of sodium.
Assay for magnesium— [note—Concentrations of the Standard preparations and the Assay preparation may be modified to fit the linear or working range of the atomic absorption spectrophotometer. ]
Lanthanum chloride solution, Dilute hydrochloric acid, Blank solution, Magnesium stock solution, and Standard preparations— Prepare as directed in the Assay for magnesium under Multiple Electrolytes Injection Type 1.
Assay preparation— Transfer an accurately measured volume of Injection, equivalent to about 20 mg (1.65 mEq) of magnesium, to a 1000-mL volumetric flask containing 50.0 mL of Lanthanum chloride solution. Dilute the contents of the flask with Dilute hydrochloric acid to volume, and mix.
Procedure— Proceed as directed for Procedure in the Assay for magnesium under Multiple Electrolytes Injection Type 1. Calculate the quantity, in µg, of magnesium (Mg) in each mL of the Injection taken by the formula:
1000(C / V)
in which the terms are as defined therein.
Assay for calcium— [note—Concentrations of the Standard preparations and the Assay preparation may be modified to fit the linear or working range of the atomic absorption spectrophotometer. ]
Lanthanum chloride solution, Dilute hydrochloric acid, and Blank solution— Prepare as directed in the Assay for magnesium under Multiple Electrolytes Injection Type 1.
Calcium stock solution and Standard preparations— Prepare as directed in the Assay for calcium under Multiple Electrolytes Injection Type 2.
Assay preparation— Transfer an accurately measured volume of Injection, equivalent to about 20 mg (1 mEq) of calcium, to a 1000-mL volumetric flask containing 50.0 mL of Lanthanum chloride solution. Dilute the contents of the flask with Dilute hydrochloric acid to volume, and mix.
Procedure— Proceed as directed for Procedure in the Assay for calcium under Multiple Electrolytes Injection Type 2. Calculate the quantity, in µg, of calcium in each mL of the Injection taken by the formula:
1000(C / V)
in which the terms are as defined therein.
Assay for chloride— Using the Injection, proceed as directed in the Assay for chloride under Multiple Electrolytes Injection Type 1.
Assay for lactate—
Mobile phase, Resolution solution, Standard preparation, and Chromatographic system— Prepare as directed in the Assay for lactate under Multiple Electrolytes Injection Type 2.
Assay preparation— Where the labeled quantity of lactate is greater than 20 mEq per liter, dilute an accurately measured volume of Injection quantitatively with water to obtain a solution containing about 0.02 mEq of lactate per mL. Where the labeled quantity of lactate is 20 mEq or less per liter, use the undiluted Injection as the Assay preparation.
Procedure— Proceed as directed for Procedure in the Assay for lactate under Multiple Electrolytes Injection Type 2. Calculate the quantity, in mEq per liter, of lactate (C3H5O3) in the Injection taken by the formula:
(C / 112.06)(L / D)(rU / rS)
in which the terms are as defined therein.
Assay for invert sugar— Using the Injection, proceed as directed in the Assay for invert sugar under Multiple Electrolytes and Invert Sugar Injection Type 1.
Auxiliary Information— Please check for your question in the FAQs before contacting USP.
Topic/Question Contact Expert Committee
Monograph Mary S. Waddell
Scientific Liaison
1-301-816-8124
(SM42010) Monographs - Small Molecules 4
Reference Standards RS Technical Services
1-301-816-8129
rstech@usp.org
USP35–NF30 Page 3026