Hyoscyamine Sulfate Injection
» Hyoscyamine Sulfate Injection is a sterile solution of Hyoscyamine Sulfate in Water for Injection. It contains not less than 93.0 percent and not more than 107.0 percent of the labeled amount of hyoscyamine sulfate [(C17H23NO3)2·H2SO4·2H2O].
Packaging and storage
Preserve in single-dose or multiple-dose containers, preferably of Type I glass, and store at controlled room temperature.
Identification
A:
The retention time of the major peak in the chromatogram of the Assay preparation corresponds to that in the chromatogram of the Standard preparation, as obtained in the Assay.
B:
After evaporation to dryness, or appropriate adjustment of concentration, it meets the requirements of the tests for Sulfate 191.
C:
The angular rotation of the Injection is levorotatory.
Bacterial endotoxins 85
It contains not more than 714.3 USP Endotoxin Units per mg of hyoscyamine sulfate.
pH 791:
between 3.0 and 6.5.
Other requirements
It meets the requirements under Injections 1.
Assay
Diluent
Use 0.01 N hydrochloric acid.
Buffer solution
Transfer 13.6 g of monobasic potassium phosphate to a 2000-mL volumetric flask, dissolve in about 1800 mL of water, adjust with phosphoric acid to a pH of 3.0 ± 0.1, dilute with water to volume, mix, and filter.
Mobile phase
With continuous stirring, add 0.3 mL of triethylamine to 1800 mL of the Buffer solution. Add 200 mL of acetonitrile, mix well, and degas.
Standard stock preparation
Dissolve an accurately weighed quantity of USP Hyoscyamine Sulfate RS in Diluent to obtain a solution having a concentration of about 0.16 mg of anhydrous hyoscyamine sulfate per mL. [noteThis solution may be stored in a refrigerator for 30 days.]
Standard preparation
Transfer 3.0 mL of the Standard stock preparation into a 100-mL volumetric flask, dilute with Diluent, to volume and mix. Calculate the concentration, C, in mg per mL, of anhydrous hyoscyamine sulfate in this solution.
Assay preparation
Transfer an accurately measured volume of Injection, equivalent to about 1.0 mg of hyoscyamine sulfate, to a 200-mL volumetric flask, dilute with Diluent to volume, and mix. Pass an aliquot through a 0.45-µm filter, discarding the first 5 mL of the filtrate.
Chromatographic system
The liquid chromatograph is equipped with a 205-nm detector and a 4.6-mm × 15-cm column that contains 4-µm packing L11 and a 3-mm × 4-mm guard column that contains packing L11. The flow rate is about 1.0 mL per minute. The column temperature is maintained at 30. Chromatograph the Standard preparation, and record the peak responses as directed for Procedure: the tailing factor is not more than 1.8, and the relative standard deviation for six replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 50 µL) of the Standard preparation and the Assay preparation into the chromatograph, record the chromatograms, and measure the area responses for the major peaks. Calculate the quantity, in mg, of hyoscyamine sulfate [(C17H23NO3)2·H2SO4·2H2O] in each mL of the Injection taken by the formula:
100 × 1.053 × (C/V)(rU / rS)
in which 1.053 is the ratio of the molecular weight of hydrated hyoscyamine sulfate to that of anhydrous hyoscyamine sulfate; C is as defined under Standard preparation; V is the volume, in mL, of Injection taken; and rU and rS are the peak responses obtained from the Assay preparation and the Standard preparation, respectively.
Auxiliary Information
Please check for your question in the FAQs before contacting USP.
Chromatographic Column
USP32NF27 Page 2603
Pharmacopeial Forum: Volume No. 31(5) Page 1373
Chromatographic columns text is not derived from, and not part of, USP 32 or NF 27.
|